رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Weapon system essential
TXT
وصف:
Mica Dielectr Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Compression
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.625 inches
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
500.0
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.813 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Los angeles class ssn (688), spruance class dd (963), nimitz class cvn, forrestal class cv, sturgeon class ssn (637), virginia class cgn (41), ticonderoga class cg (47), kidd class ddg, arleigh burke class ddg
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
10.0 gigohms
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -35.0 degrees celsius and 85.0 degrees celsius
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+75.0/+380.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
175.0 dc continuous single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
-1.50/+0.30 single section and -1.50/+0.50 single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 slotted screw
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 printed circuit