رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
End connections modified by air dry corp
MRC:
The length of a straight line which passes through the center of an aperture,and terminates at the circumference.ABVL
Aperture Diameter:
0.500 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
240.0 degrees fahrenheit single response
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.000
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The difference,at the rated temperature,between the inlet and outlet pressure for positive operation.CQCP
Inlet/outlet Operating Pressure Differential:
150.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch single response
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polytetrafluoroethylene flow control device
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090