رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Assembly includes p/n k884087-403 (generator), p/n k884087-305 (splined coupling shaft), p/n k884087-007 (spline adapter), p/n m83248/1-110 (o-ring), mil-g-21164d (molybdendum disulfide grease), and p/n p17734 (back-up ring); adding spline adapter increases length to 16.230 inches , changes coupling shaft end from 6 to 16 spline, with a root diameter of 0.725 to 0.733 inch, and shaft (major) diameter of 0.812 to 0.817 inch
TXT
وصف:
Alternating Current Generator
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
15.230 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
7.360 inches
MRC:
The length of a straight line which passes through the center of the smallest cross section of a spline,and terminates at the circumference.AAUH
Spline Minor Diameter:
0.470 inches single end
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
6 single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.598 inches single end and 0.600 inches single end
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Sh-2g helicopter
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
15000.0 feet
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open protected
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
6 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated and separately ventilated
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
30.0 kilovolt-ampere output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.520 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-40.0 operating degrees celsius and 71.0 operating degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
11100.0 low full load and 12600.0 high full load or 15200.0 high no load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
5.000 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
110.0 konica, c six spline output
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A14 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
380.0 output or 420.0 output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 threaded stud