رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
30 pos cont switch; demagnetization
TXT
وصف:
Portabl Magnetic Inspection Unit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
7cables: 10 ft 2/o w/connectors 2, 15 ft 4/o w/connectors 4; contact prds 1 pr; red paste 1lb; black and red powder 1 lb ea; remote cont cable ext; remote cont cable and pushbutton; residual field indicator spray gun 1; contact clamps 2; powder bulbs
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
3000.0
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0 and 440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-5.6
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to inspect ferromagnetic materials and parts by means of the magnetic particle inspection method.
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
70-04-01
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33b2-4-11 and t.O. 33b2-4-14
MRC:
Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
Relationship To Similar Equipment:
INTE-RC-HAN-GEAB
MRC:
The alpha-numeric-alpha designation used to identify the type and/or model of the basic item.TMDN
Type/model Designation:
Kch-3g