رقم الجزء KRFC1200

Cartridge Fuse

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
krfc1200
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
000305138
NSN
رقم المخزون الوطني:
5920-00-030-5138 5920000305138
TXT
وصف:
Cartridge Fuse
INC
INC
رمز اسم العنصر:
00248
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Split terminal type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.500 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
3.250 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
8.500 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.000 inches
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
1200.000
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.312 inches
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Err Default:
2.000 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
600.0 ac
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Time delay
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Opaque body
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Nonrenewable fusible element
MRC:
The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
Circuit Over-current Interruption Delay Time In Seconds:
4.0 500 pct of current rating
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
20000.0

{lang[cimilar]} Cartridge Fuses

« Fuses, Arrestors, Absorbers and Protectors {lang[catalog]}
قارن الآن»
واضح | أخفى