رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Universal
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
125.0 degrees fahrenheit single response
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.290 and 0.180
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
250.0 pounds per square inch single response
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
440.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy seat
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel flow control device