رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Converter, regulator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.700 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
P3 orion
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
55000.0 feet
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
20.0 dc volts single operating power rqmt and 40.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 dc volts single power output and 28.0 dc volts single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+71.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
300.0 watts single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
25.0 millivolts peak single power output
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Functional description a pulse width modulated dc to dc converter that provided regulated multiple output power; converts transforms an unregulated 28 vdc to a regulated adjustable dc output via a remote control potentiometer or voltage for voltage controlled models; primarily designed to control the light intensity of incandescent bulbs in lighting systems; input voltage 28 vdc ; output voltage adjustable with external 5k ohm, 1/2 w rheostat or voltage 0-5 v dc; regulation 2 pct for line, 2 pct load and 2.5 pct temperature; common mode isolation 40 db; output ripple 25mv p-p or less; protection overvoltage output voltage is limited to aproximately 125 pct of rating even though remote control rheostat opens or internal failure occurs; output current 11 adc total; efficiency 84