رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Cage: conduit, shielding, emi/emp, mil-prf-24758 (sh)
TXT
وصف:
Flexible Metal Conduit
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.500 inches
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Flame resistant
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.890 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
12.000 inches
MRC:
Indicates the type of the material,form,and/or finish of woven metal braid applied over the inner core for protection and suppression of electrical interference.ACKE
Braided Metallic Shield Type:
Bronze wire
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
2.500 inches
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Material: metal core: brass, wire over-braid: phosphorous bronze emi shield, jacket: bluejacket material (low-smoke per nes 711, halogen-free, flame-resistant per iec 60614-1 and functional between m65.0 and p200.0 degrees celsius
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber synthetic outer covering
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Plain conduit
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Jacket material solar weathering tested to equivalent of 56 yrs per iec 60068-2-5; toxicity index: 1.9 per nes 713; meets both us navy and aerospace fluid reqs; fully compatible with mil-c-24758 adapters; jacket covering is haze-gray in color per federal standard 595b no. 26270