وصف:
Electrolytic Fixed Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
W/o mtg facilities, axial terminals
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
1.000
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 1.250 inches and 1.750 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 0.266 inches and 0.296 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.907 inches and 0.969 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
Between 0.030 inches and 0.040 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
Electrod (s) grounded to case, w/gnd terminal
MRC:
The total opposition offered to the flow of an alternating or pulsating current,expressed at minimum operating temperature in ohms.AECN
Impedance At Minimum Operating Tempurature In Ohms:
910.0
MRC:
An indication of whether or not the item normally will accept flow of current in one direction only.AECQ
Electrical Polarization:
Polarized
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5999-01-174-0693 processor, display
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
3.300 microfarads single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 85.0 degrees celsius
MRC:
Stray direct current of relatively small value which flows through the item when voltage is impressed across it,measured at maximum operating temperature.CQLH
Dc Leakage At Maximum Operating Temp:
24.0 microamperes
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
250.0 dc single section
MRC:
The limits of permissible deviation per section of a measured value from a specified value.CRTP
Tolerance Range Per Section:
-10.00/+30.00 percent single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Metal
MRC:
The chemical compound or mechanical mixture properties of which the capacitive electrode is fabricated.CWNJ
Capacitive Electrode Material:
Aluminum
MRC:
All internal series resistances concentrated or lumped at one point in the circuit and treated as one resistance,measured at reference temperature in ohms.CWQC
Equivalent Series Resistance At Reference Tempurature In Ohms:
40.19
MRC:
Stray direct current of relatively small value flows through the capacitor when voltage is impressed across it,measured at reference temperature.CWQH
Dc Leakage At Reference Temp:
4.000 microamperes
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The chemical compound or mechanical mixture properties of which the case insulation is fabricated.CWSZ
Case Insulation Material:
Plastic
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-39018 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-39018/1 government specification