رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electrical Receptacle Connector
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape, external coupling
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.250 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.800 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock proof and vibration resistant
Distance From Mounting Shoulder To Front Face:
Between 0.706 inches and 0.843 inches
Mounting Facility Thickness:
Between 0.045 inches and 0.240 inches
MRC:
Indicates the type of threaded device included on the item.AFQR
Threaded Device Type:
Mounting bushing
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
Bnc single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end single contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
500.0 single mating end single contact grouping
MRC:
The maximum frequency at which the contact is rated.AFRF
Contact Maximum Frequency Rating:
4000.0 megahertz single mating end single contact grouping
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Bayonet pin
MRC:
The means by which the connector cable is relieved of stress and strain.AFRW
Connector Cable Strain Relief Method:
Compression nut
MRC:
The impedance for which the item is designed for maximum power transfer,expressed in ohms.AFRY
Radio Frequency Type Contact Characteristic Impedance In Ohms:
50.0 single mating end single contact grouping
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
28
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.500 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold single mating end single contact grouping
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the contact surface treatment material.CRBJ
Contact Surface Treatment Specification:
Mil-g-45204, type 2, class 2 military specification single treatment response single mating end single contact grouping
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Solder well single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Copper alloy
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
1 single mating end single contact grouping
MRC:
The physical configuration of the hole designed to accommodate a bushing.CXCJ
Bushing Accommodation Hole Shape:
Round w/flat
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Coaxial socket single mating end single contact grouping
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact surface gold
MRC:
An indication of the precious material contained in the item,and the amount per a measurement scale.PMWT
Precious Material And Weight:
0.005 gold grains, troy
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-39012 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-39012/19 government specification