رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
5 fuseholders
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Pile-up and nonpile-up symmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
56 single section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
4 single section front
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
1.5 lowest dc voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
115.0 ac at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
115.0 highest dc voltage rating at sea level
MRC:
The position of the actuator,with relation to the extremity of rotation,that is momentary (spring loaded).CQQT
Switch Actuator Momentary Position:
Clockwise single actuator and counterclockwise single actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
4 single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, plug
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Makes before breaks, breaks before makes single section front
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
45.0 degrees single actuator
MRC:
Indicates the type of device included in the switch to limit the angular rotation of its actuator.CTDN
Switch Actuator Stop Device Type:
Adjustable stop single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
2.0 amperes resistive load highest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
25.0 microamperes resistive load lowest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
7.5 amperes resistive load ac at sea level and 10.0 amperes resistive load ac at sea level