رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Liquid Impeller Type Meter
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
125.0 pounds per square inch
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Drilled flange
MRC:
A measurement of the smallest dimension of an inlet flange,in distinction from length or width.ACRF
Inlet Flange Thickness:
0.375 inches
MRC:
A measurement of the longest dimension of the inlet flange,in distinction from width.ACRG
Err Default:
Err default
MRC:
A measurement of the longest dimension of the inlet flange,in distinction from width.ACRG
Inlet Flange Length:
3.500 inches
MRC:
A measurement taken at right angles to the length of the inlet flange,in distinction from thickness.ACRH
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the inlet flange,in distinction from thickness.ACRH
Inlet Flange Width:
3.500 inches
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.500 inches
MRC:
The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
Inlet Bolt Circle Diameter:
3.625 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Propeller
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Direct mount
MRC:
Designates the size of the inlet connection included on the item.ANHY
Inlet Connection Size:
1.812 in. Id
MRC:
An indication of the unit of measure for which the item is designed.ANSX
Measurement Unit:
Us gallon
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+9999.0
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Square
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Drilled flange
MRC:
The physical configuration of the outlet flange.ARTL
Outlet Flange Shape:
Square
MRC:
Indicates the location for which the item is designed to be installed.AYNY
Installation Location:
Left hand side or right hand side
MRC:
The volume of liquid flowing through the item in a given period of time.BHCC
Liquid Flow Rate:
60.0 gallons per minute
MRC:
An indication of whether or not the item is provided with a straightening vane/s/.BHCF
Straightening Vane:
Not provided
MRC:
Indicates the type of register provided on the item.BHCG
Register Type:
Wheel
MRC:
An indication of whether or not the item is provided with a reset feature.BHCH
Reset Feature:
Provided
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
1.812 in. Id
MRC:
A measurement taken at right angles to the length of the outlet flange,in distinction from thickness.BHCP
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the outlet flange,in distinction from thickness.BHCP
Outlet Flange Width:
3.500 inches
MRC:
A measurement of the longest dimension of the outlet flange,in distinction from width.BHCQ
Err Default:
Err default
MRC:
A measurement of the longest dimension of the outlet flange,in distinction from width.BHCQ
Outlet Flange Length:
3.500 inches
MRC:
A measurement of the smallest dimension of an outlet flange,in distinction from length or width.BHCR
Outlet Flange Thickness:
0.375 inches
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
3.625 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.500 inches