رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
m8715700101axc
TXT
وصف:
Optoelectronic Control-display
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.515 inches and 0.545 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.185 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.400 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
7.0 volts
MRC:
Indicates the type of characters on the item.ANHC
Character Type:
Numeric
MRC:
The number of characters per line.ANML
Character Quantity Per Line:
1
MRC:
The number of lines provided.APAJ
Line Quantity:
1
MRC:
Indicates the type of control.AQZF
Control Type:
Decoder and driver
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The hue or tint of the display.CTQH
Display Color:
Red
MRC:
The measurement of luminous flux in a given direction per unit of solid angle.CTSB
Luminous Intensity:
Between 44.0 microcandela and 79.0 microcandela
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Terminal surface option gold
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-d-87157 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 pin
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-d-87157/1 government specification