رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
With internal balance relay, 160 degrees stroke, 60 sec timing
TXT
وصف:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
7.500 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
7.4375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
5.625 inches
MRC:
The additional parts supplied with the item which may be required for application.AFHR
Accessory Components:
Case
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise identical ends or counterclockwise identical ends
MRC:
The required purpose or application for which the item is designed.ANTN
Specific Use:
Damper or valve drive
MRC:
The shortest straight line between flats,perpendicular to the height.ASDB
Width Across Flats:
0.3750 inches identical ends
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 threaded hole and 4 unthreaded hole
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
150.0 foot-pounds running
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The distance between the center of the shaft to the mounting surface.CWDM
Shaft Center To Mounting Surface Distance:
3.34375 inches identical ends
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.063 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-40.0 operating degrees fahrenheit and 125.0 operating degrees fahrenheit
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.875 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
24.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A15 single style identical ends
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 input or 60.0 input