رقم الجزء MF-R017

Inclosed Link Fuse

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
mf-r017
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
016014055

معلومات الجزء
Mf-r series-ptc resettable fuses

NSN
رقم المخزون الوطني:
5920-01-601-4055 5920016014055
TXT
وصف:
Inclosed Link Fuse
INC
INC
رمز اسم العنصر:
00249
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Plug in limiter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.3 millimeters
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
7.6 millimeters
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
5.1 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.1 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.4 millimeters
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
12.7 millimeters
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
1.7
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Err Default:
0.51 millimeters
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
60.0 ac
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Delay time
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
No visual indication
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
40.0