رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Cover included
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Block type
MRC:
The structural characteristic(s) of the board.ABCX
Board Construction:
Solid construction
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.093 inches
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.875 inches
Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole:
0.269 inches
Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility:
0.203 inches
Boardlength:
2.500 inches
Board Thickness:
0.562 inches
MRC:
The direction of the mounting thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ADNE
Err Default:
Err default
MRC:
The direction of the mounting thread when viewed axially.a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ADNE
Mounting Thread Direction:
Right-hand
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance,and an external or internal threaded mounting facility.AKBM
Mounting Facility Thread Class:
2a
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread on the mounting facility.AKEM
Err Default:
Err default
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread on the mounting facility.AKEM
Mounting Facility Thread Pitch Diameters:
+0.0072 to 0.0500 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale applied to a mounting facility diameter.CDTD
Mounting Facility Thread Series Designator:
Unc
MRC:
The number of threads on the mounting facility per linear inch measured on a line parallel to the thread axis.CDTG
Mounting Facility Thready Qty Per Inch (tpi):
20
MRC:
Indicates the type of nonfeedthru terminal furnished with the item.CRNL
Nonfeedthru Terminal Type:
598 single
MRC:
The number of nonfeedthru terminals furnished with the item.CSCS
Nonfeedthru Terminal Quantity:
2 single
MRC:
The length of a straight line which passes through the nominal threaded portion,and terminates at the circumference.CWKZ
Mounting Facility Thread Diameter:
0.250 inches
MRC:
The arrangement of terminal positions on the item.CWLG
Terminal Pattern Arrangement:
Random
MRC:
The design of the terminal.CWLN
Terminal Design:
Nonfeedthru
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyester board and glass fiber board
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-m-14, type mai-60 military specification single material response board