رقم الجزء MILC1939TYPEA

Circuit Breaker

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
milc1939typea
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
001790094
NSN
رقم المخزون الوطني:
5925-00-179-0094 5925001790094
TXT
وصف:
Circuit Breaker
INC
INC
رمز اسم العنصر:
00136
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.219 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal or plastic
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
50.0 amperes dc single location
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
24.0 dc single location
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc single location
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent single location
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Thermal-magnetic single location
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay single location
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
1 toggle
MRC:
Denotes the action imparted by actuator operation.CPRW
Actuator Function:
Trip-reset
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
10.000 at 200 pct single location and 100.000 at 200 pct single location
MRC:
The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
Trip Release Ambient Tempurature Rating:
50.0 degrees celsius single location
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 threaded stud
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
A type

{lang[cimilar]} Circuit Breakers

« Circuit Breakers {lang[catalog]}