رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
milm17060servicea
TXT
وصف:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
13.938 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
25.062 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
15.500 inches
MRC:
The length of a straight line which passes through the center of the smallest cross section of a spline,and terminates at the circumference.AAUH
Spline Minor Diameter:
1.040 inches single end and 1.050 inches single end
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
6 single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
1.246 inches single end and 1.247 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end or counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Watertight
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
1.2500 inches single end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
8 unthreaded hole
MRC:
The acceptable time limits for the item.BFLT
Time Interval:
1.0 hours on
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Fan cooled
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Vertical mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
10.0000 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.062 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
40.0 operating degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
10.000 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1800.0 single no load and 1740.0 single full load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
14.000 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
440.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A14 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead