رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
model1007-1006-115dc
TXT
وصف:
Electrical Counter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.890 inches and 3.950 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 2.500 inches and 2.525 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.730 inches and 1.740 inches
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
Between 3.307 inches and 3.317 inches
MRC:
The shortest distance between mounting centers parallel to the horizontal plane.AFDT
Shortest Horizontal Distance Between Mounting Centers:
Between 3.225 inches and 3.235 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
Between 1.350 inches and 3.360 inches
MRC:
The shortest distance between mounting centers parallel to the vertical plane.AFDW
Shortest Vertical Distance Between Mounting Centers:
Between 0.870 inches and 0.880 inches
MRC:
The number of register(s) contained in the item.ANQD
Register Quantity:
1
MRC:
The number of digits displayed on each register of the item.ANQS
Figure Quantity Per Register:
6 single register single tier
MRC:
A measurement from the bottom to the top of the figure.ANQT
Figure Height:
0.185 inches single register single tier and 0.195 inches single register single tier
MRC:
The maximum number of counts the item can accomplish in a measured time.ANRE
Maximum Count Rate:
1000.0 per minute single register single tier
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Eight position staggered
MRC:
The means used to return the register/s/ to original position.AXEC
Register Reset Method:
Total counter manual single register single tier
MRC:
The mathematical function the register/s/ is designed to perform.AXED
Register Function:
Add single register single tier
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
8 unthreaded hole
MRC:
Indicates the type of mounting for which the item is designed.BCNX
Mounting Type For Which Designed:
Panel rear single register single tier
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 dc
MRC:
The means by which the display of the numeral is provided.CSWS
Numeral Display Method:
Drum
MRC:
The readout of the numerals displayed by the item.CSWT
Numeral Readout:
00000 single register single tier and 99999 single register single tier
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black single register single tier figure background
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White single register single tier figure
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Electrical cased
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead