رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Instrument Shunt
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of mounting provisions provided.ABDS
Mounting Provision Quantity:
2
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.937 inches and 2.063 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
Between 0.865 inches and 0.885 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 1.187 inches and 1.313 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.563 inches and 1.688 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.202 inches and 0.208 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Nut 4; washer 4
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
External
MRC:
The element,compound,or mixture of which the element is fabricated,excluding any surface treatment.AQCW
Element Material:
Copper-manganese-nickel alloy
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
8.055 cubic inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
One side
MRC:
The loss of potential resulting from the inherent opposition to the flow of electricity across the item,expressed in millivolts.CRCM
Voltage Drop In Millivolts:
40.0
MRC:
Indicates the type of current and the rated value for which the item is designed.CRCT
Current Rating And Type:
107.0 amperes dc
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Conforms to mil-s-61
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Electrical, electronic properties measuring and test instruments