رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Fueling Centrifugal Pumping Unit
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
2
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
2
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
Indicates the type of discharge connection.ASHJ
Discharge Connection Type:
Flanged
MRC:
The rated horsepower of the electric motor.ASHK
Electric Motor Horsepower Rating:
12.5
MRC:
Indicates the type of pump provided for circulating liquid.ATDA
Liquid Circulating Pump Type:
Radial flow
MRC:
The maximum rated fueling capacity delivered by the item.AWQT
Maximum Fueling Capacity Rating:
150.0 gallons per minute
MRC:
The speed of the fueling required to produce its rated capacity,expressed in revolutions per minute.AWQW
Fueling Operating Speed At Rated Capacity In Rpm:
3450.0
MRC:
The maximum rated defueling capacity delivered by the item.AWQY
Maximum Defueling Capacity Rating:
100.0 gallons per minute
MRC:
The speed of the defueling required to produce its rated capacity,expressed in revolutions per minute.AWQZ
Defueling Operating Speed At Rated Capacity In Rpm:
3450.0
MRC:
An indication of the suction connection characteristic(s).AWZC
Suction Connection Characteristic:
Common
MRC:
Indicates the type of suction connection/s/ integral with the item.AWZD
Suction Connection Type:
Flanged
MRC:
The identifying numeric code of the originator that controls or manufactures the electric motor.AWZF
Electric Motor Manufacturer Code:
07524
MRC:
The speed of the electric motor,expressed in revolutions per minute.AWZG
Electric Motor Rpm:
3450.0
MRC:
An indication of whether or not a primer pump is included.AWZK
Primer Pump:
Included
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the electric motor per specified document.AWZL
Electric Motor Inclosure Type Per Specificationified Document:
Explosion proof mil-std-108 or fan cooled mil-std-108
MRC:
An indication of whether or not an air eliminator is included.AWZM
Air Eliminator:
Included
MRC:
An indication of whether or not a magnetic amplifier/s/ is included.AWZN
Magnetic Amplifier:
Included
MRC:
Designates the size of the suction connection included on the item.AYZR
Suction Connection Size:
4.000 n std
MRC:
Designates the size of the discharge connection included on the item.AZFC
Discharge Connection Size:
2.500 n std
MRC:
An indication of whether or not a separate electric motor is included.AZFD
Separate Electric Motor:
Included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
2
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Explosion proof motors