رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Temperature monitor for microprocessor systems
TXT
وصف:
Linear Microcircuit
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.90 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+125.0 degrees celsius
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Monitors local and remote temperature
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
No calibration required, programmable overtemperature / undertemperature alarm, 5.5v tolerant, smbus 2-wire serial interface up to 100 khz
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Plastic shrink small outline package, 16 leads, body width 3.9mm, lead pitch 0.635mm