رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Switched frequencies 125/250 mhz
TXT
وصف:
Antenna Alignment Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
3.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
5.500 inches
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
C/o test oscillator model 210, nato nsn 6625-99-777-4431 ensures the homing circuits and indicators of receiver are working properly; extension cables nf-00-545 with multi-way connectors, 15 in; adjusting tool jt10040, t handled; mates w/ each of 4 balance adjust ratchet switches located on homing receiver; pp3 dry cell housed in separate internal compartment of test oscillator; indicator led lamp; flexible, detachable helical whip antenna with bnc connector; padded carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Performs homing system receiver alignment & confidence checks after removal & replacement of system's lrus
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Tests function of homing receiver, indicator, and two broad band antennas
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
2.250 inches
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Homing receiver must be removed from operator's control panel to access the rear of unit, a cover plate must be removed from the rear panel of homing receiver to access ratchet switch