رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Pc-251-123a lightweight static inverter
TXT
وصف:
Static Power Inverter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
177.8 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
69.9 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
127.0 millimeters
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Fixed wing and helicopter qualified
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bolt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
24.0 dc volts 2nd operating power rqmt and 32.0 dc volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
28.0 dc volts 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
26.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
115.0 ac volts 1st power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+71.0 degrees celsius
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
11.9 dc amperes 1st operating power rqmt
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Output configuration monophase sinewave; efficiency 75 pct ; unit has reverse polarity protection; frequency monitor automatically shuts the inverter off should the frequency drift below 370 hz or above 430 hz; faultmonitor provides 27 vdc output at 100 ma to an annunciator device under normal condition; no power is available under fault conditions; cooling hi-rel blower; environmental conditions rfi emission meets rtca do-160a cat z; mating connector ms3476l14-9s