رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Power pac 14amp/hr (2 7a/h batteries) power supply with batterty backup
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.300 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.500 inches
MRC:
The number of batteries required for operation.AEXR
Battery Quantity:
2
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Virginia class ssn-774; power pace 14a
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Case
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
1.0 single power output
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour dry 1st operating power rqmt and 230.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
13.600 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz single power output and 60.0 hertz single power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
2 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Switch single power output and current limit single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Standby switch and circuit overload protection device and calibrated output signal and battery condition meter and auto parallel operating and fuse and indicator light and over voltage protector and over temperature protection and over current protector
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
14.0 ac amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
1.0 volts average single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal cap single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
7.0 ac amperes 1st operating power rqmt and 7.0 ac amperes 1st operating power rqmt
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
The time required for a battery power supply to switch from standby mode to full rated output power.CXMN
Battery Switching Time:
Instantaneous
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Designed for critical base stations and repeater sites that must remain "on-linle" even in event of ac power failure