رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
30.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
24.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 208.0 volts and 460.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 47.0 hertz and 63.0 hertz
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Multiple stages
MRC:
Indicates the type of charger furnished.AKWH
Charger Type:
Solid state semiconductor
MRC:
The voltage the unit is designed to deliver,expressed in volts.AKWL
Charging Voltage In Volts:
Between 30.0 and 45.0
MRC:
The current output rating which the item delivers,expressed in amperes.AKWM
Charging Current Rating In Amps:
140.000
MRC:
The means provided for controlling the current output.AKWP
Charging Regulation Method:
Controlled
MRC:
The number of cells contained in the item.AQGQ
Cell Quantity:
18
MRC:
Indicates the type of battery/ies/ for which the item is designed.AQYH
Battery Type For Which Designed:
Lead-acid
MRC:
The number of alternating current phases.FAAZ
Phase:
Three