رقم الجزء PS387065.03

Circuit Breaker

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
ps387065.03
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
015193248

معلومات الجزء
Circuit breaker fast, push/pull

NSN
رقم المخزون الوطني:
5925-01-519-3248 5925015193248
TXT
وصف:
Circuit Breaker
INC
INC
رمز اسم العنصر:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
12.0 millimeters
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
35.0 millimeters
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
17.3 millimeters
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
27.8 millimeters
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
44.5 millimeters
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes dc single location
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
65.0 dc single location
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
50.0 dc single location
MRC:
Indicates the type and voltage rating required to operate the auxiliary /remotely actuated/ trip actuator,expressed in volts.CPRK
Auxiliary Trip Coil Voltage Type And Rating In Volts:
3000.0 ac single location
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay single location
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
1 push-pull
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.500 inches
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Mounting facility threadneck; color black; mounting size 12 mm high, d shape; c w 2 hex nuts, 1 washer with locating pin; 1 legend plate; actuactor black color and without marking; auxiliary contact one change over per pole; internal circuit series trip; no remote trip; no illuminated; auxiliary circuit 2 a, 30 v dc; typical life 10, 000 operations; ambient temperature m40.0 to 70.0 degrees c; interrupting capaci type 500 a at 50 v dc; vibration 10 g porm 0.76mm; shock 50 g; corrosion 96 hours at 5 pct sale mist; humidi type 240 hours at 95 pct rh; mass approx 30 g
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 knife blade

{lang[cimilar]} Circuit Breakers

« Circuit Breakers {lang[catalog]}
قارن الآن»
واضح | أخفى