رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Battery Power Supply
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
134.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
43.0 millimeters
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
90.0 ac volts and 265.0 ac volts single operating power rqmt
MRC:
The value,or range of values,of output of the power supply.AWNP
Power Supply Output Voltage Rating:
23.0 volts and 29.0 volts single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-25.0 to 70.0 degrees celsius
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
75.0 watts single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit overload protection device and over voltage protector
MRC:
An indication of whether current or voltage or both are controlled,stabilized,or limited to obtain the required output power characteristics.CWGW
Power Supply Output Current/voltage Characteristics:
Constant current single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
0.6 ac amperes single operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Connector, receptacle single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
Indicates the location of the battery.CWJF
Battery Location:
Internal
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Air cooled