رقم الجزء R10E1Y6Y430

Electromagnetic Relay

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
r10e1y6y430
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
007820297
NSN
رقم المخزون الوطني:
5945-00-782-0297 5945007820297
TXT
وصف:
Electromagnetic Relay
INC
INC
رمز اسم العنصر:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.405 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.734 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.375 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
430.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded stud single mounting facility
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
56.0 milliamperes dc single winding
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.008 seconds fixed release time
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.015 seconds fixed operate time
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
24.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
1.0 amperes ac resistive load and 1.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 29.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
18 wire lead energizing element
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead contacts

{lang[cimilar]} Electromagnetic Relaies

« Relays and Solenoids {lang[catalog]}
قارن الآن»
واضح | أخفى