رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electronic Marker Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
22.000 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
17.000 inches
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5840-00-342-6382, radar set, an/fps-20
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Cylindrical
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
150.000 ohms output channel
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
1.000 volts output channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Output channel azimuth
MRC:
The number of available reference points.BHWB
Reference Point Quantity:
3
MRC:
The value represented by the generated reference points.BJBC
Reference Point Value:
0.088 degrees
MRC:
The value represented by the generated reference points.BJBC
Reference Point Value:
10.000 degrees
MRC:
The value represented by the generated reference points.BJBC
Reference Point Value:
30.000 degrees
MRC:
The number of reference points that are intensified.BJBF
Err Default:
Err default
MRC:
The number of reference points that are intensified.BJBF
Intensified Reference Point Quantity:
30
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
120.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Dprovides azimuth markers of precise characteristics with respect to amplitude, shape, duration, and recurrence as received by antenna for use on the plan position indicator scopes and by the computer
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
4, 096 pulses per antenna revolution; angle mark; 1 north marker present; components: 2 selsyn, 2 photo electric cell, 2 lamp, 1 gear train and slotted disk, 2 cathode follower, 1 power supply; mounts on antenna pedestal; incl. Angle mark switch and 1x and 36x synchro outputs; externally synchronized by antenna drive system; sine wave; positive or negative polarity