رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
rb9s5-r23mm120240
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
240.0 degrees fahrenheit single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
300.0 pounds per square inch single response
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.625 inches all ends
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polytetrafluoroethylene flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber butadiene-acrylonitrile class nbr seat
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090