رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
rbl-2103-00327
Actuator Height:
0.343 inches
MRC:
The hue or tint of the actuator when illuminated by an integral light source.AFVB
Illuminated Actuator Color:
Amber single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
1.000 amperes resistive ac
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 cable w/connector