رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
May also be powered by jp-5 jet fuel or diesel light oil
TXT
وصف:
Diesel Engine Generator Set
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac and dc
MRC:
The direct current rating for which the item is rated,expressed in amperes.ACUT
Direct Current Rating In Amps:
8.3
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
12.0 volts
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5000e portable generator set
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed
MRC:
An identifying number assigned by the government agency or commercial organization controlling the item.AMSB
Identifying Number:
Rgd5000e model no.
MRC:
The name of the manufacturer.AQGA
Manufacturer Name:
Norwall power systems
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
4500.0 watts
MRC:
The direct current for which the item is rated,expressed in watts.AYHA
Dc Wattage Rating:
100.0 watts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
120.0 and 240.0
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Exciter
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Voltage regulator: condensor type; frequency: 60 hz; fuel tank capacity: 4.23 gallons (16.0l); 8.0 hours continuous hours; power factor: 1.0; engine model: dy41d