رقم الجزء RMA-11-BV

Flow Rate Indicating Meter

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
rma-11-bv
تجريد:
Yes - DEMIL/MLI
صلاحيه:
وحدة القياس:
NIIN:
011155275
NSN
رقم المخزون الوطني:
6680-01-115-5275 6680011155275
TXT
وصف:
Flow Rate Indicating Meter
INC
INC
رمز اسم العنصر:
38346
INC
COM
امتثال:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.812 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/mpq-t3 radar
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Brass metering valve, 1
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Cc air/min
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Plastic
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface panel
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+30.0/+240.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
0.125 in. Npt
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Not included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Guided
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Any acceptable
MRC:
Indicates the type of guide provided.BMHW
Guide Type:
Any acceptable
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
100.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
0.125 in. Npt
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
10cc
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

{lang[cimilar]} Flow Rate Indicating Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments {lang[catalog]}
قارن الآن»
واضح | أخفى