رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
s04-80010a1c2e2j3l2n1g13suppr-
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Moisture proof
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.740 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.740 inches
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.740 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Rectangular
MRC:
A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
Actuator Width:
0.740 inches
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
White single actuator
MRC:
The hue or tint of the actuator when illuminated by an integral light source.AFVB
Illuminated Actuator Color:
Green single actuator
MRC:
Words,letters,numbers,symbols,or any combination thereof,permanently inscribed on the actuator,excluding the part number.AFVE
Actuator Inscription:
Suppr.Agilite single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 pole, double throw, one position momentary single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
5.000 amperes resistive dc and 2.500 amperes inductive dc and 1.500 amperes lamp dc and 5.000 amperes resistive ac and 2.500 amperes inductive ac and 1.500 amperes lamp ac
MRC:
A reference number exceeding 32 positions.ELRN
Extra Long Reference Number:
S04-80010a1c2e2j3l2n (g) 13suppr.Agilite
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
11 socket, integrated wire termination
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by extra long reference number