رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3a single pressure connection
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.550 inches single pressure connection
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Waterproof and corrosion resistant and fungus resistant
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.500 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.438 inches single connection
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.325 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.750 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
The shortest straight line between flats,perpendicular to the height.ASDB
Width Across Flats:
0.750 inches
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 300.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Line
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.438 inches single pressure connection
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
1.0 amperes resistive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point not adjustable and deactuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
33.00 actuation point pounds per square inch gage and 40.00 actuation point pounds per square inch gage and 3.00 deactuation point pounds per square inch gage and 40.00 deactuation point pounds per square inch gage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level single voltage
MRC:
Indicates the type of pressure connector.CTZL
Pressure Connector Type:
Flared, threaded external single connection
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single pressure connection