رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
12.5 ghz to 13.5 ghz frequency
TXT
وصف:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b first flange all connection facilities
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand first flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.747 inches first flange and 0.753 inches first flange0.685 inches second flange and 0.687 inches second flange
Flange Inside Height:
0.372 inches first flange and 0.378 inches first flange0.479 inches second flange and 0.481 inches second flange
Flange Outside Width:
1.485 inches first flange and 1.515 inches first flange1.485 inches second flange and 1.515 inches second flange
Flange Outside Height:
1.485 inches first flange and 1.515 inches first flange1.485 inches second flange and 1.515 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.485 inches first flange and 0.515 inches first flange0.376 inches second flange and 0.406 inches second flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches first flange all connection facilities and 0.141 inches first flange all connection facilities0.144 inches second flange all connection facilities and 0.141 inches second flange all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.10
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
45.0 pounds per square inch gage
Waveguide Outside Width:
Between 0.847 inches and 0.853 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches first flange all connection facilities
Waveguide Inside Width:
Between 0.747 inches and 0.753 inches
Waveguide Inside Height:
Between 0.372 inches and 0.378 inches
Waveguide Outside Height:
Between 0.472 inches and 0.478 inches
Waveguide Longer Offset Distance:
Between 1.667 inches and 1.707 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole first flange all connection facilities4 unthreaded hole second flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type first flangecover type second flange
Waveguide Offset Distance:
Between 1.667 inches and 1.707 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy single flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Bend type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc first flange all connection facilities