رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
scl7608btypeu532pps4
TXT
وصف:
Gasoline Engine Generator Set
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Shock
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
27.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac and dc
MRC:
The direct current rating for which the item is rated,expressed in amperes.ACUT
Direct Current Rating In Amps:
2.5 and 17.0
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 24.0 volts and 35.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The maximum weight that the item is designed to support.AERL
Maximum Weight Capacity:
60.000 pounds
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. An/pps-4
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The name of the item as assigned by the controlling government agency.AKSJ
Item Name Assigned By Government Agency:
Generator set, gasoline engine
MRC:
An indication of whether or not winterization is included.AMWJ
Winterization Feature:
Not included
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
300.0 watts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
115.0
MRC:
The ratio between actual rated power,and power required by a specified load applied to the item,expressed in percent.AYHD
Power Factor In Percent:
0.9
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Manually by rope
MRC:
An indication of whether or not an automatic starting feature is provided.AZBM
Automatic Starting Feature:
Not provided
MRC:
The number used by the manufacturer for identifying the prime mover.AZBP
Prime Mover Identifying Number:
591j99-2 model no.
MRC:
Indicates the type of housing provided.AZCB
Housing Type:
Inclosed
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
-28.9 and 51.7
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
75.0
MRC:
An indication of whether or not radio interference suppression is included.AZKT
Radio Interference Suppression:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single