رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Double solenoid operation; 0.26 amps inrush
TXT
وصف:
Directional Control Linear Valve
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
5
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Nimitz class cvn
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.1
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal pipe
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Side ported
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
150.0 pounds per square inch air
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
160.0 degrees fahrenheit air
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
120.0 ac
MRC:
The number of fl0w patterns provided.CYGY
Flow Pattern Quantity:
2
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt