رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Radio Frequency Transmiss Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.050 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.250 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz single frequency operating and 18.0 gigahertz single frequency operating
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.50 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.50 single
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The design of the connector end.AHUD
Connector End Design:
Female
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
2.0 watts average single
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
60.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
4
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
7
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 receptacle, coaxial and 3 tab, solder lug