رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Environmentals of temp, vibration, shock, humidity and altitude
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.320 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.900 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The commercial and government entity (cage) code of the government agency,industrial organization,or other source,which controls the document.AJJY
Document Source:
80063
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hole
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
180.0 ac pounds per hour dry 1st operating power rqmt and 220.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
103.5 ac pounds per hour dry 2nd operating power rqmt and 126.5 ac pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
23.5 dc volts single power output and 24.5 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
380.0 hertz 1st operating power rqmt and 420.0 hertz 1st operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-65.0/+125.0 degrees celsius
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
0.275 volts peak single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Solder post single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Solder post 1st operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Solder post 2nd operating power rqmt
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Converters, elect., nonrotating