رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.125 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACRX
Inlet Thread Direction:
Right-hand
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
6.500 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Dry
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Air
MRC:
The basic design of the muffler.ARND
Muffler Design:
Baffle
MRC:
The number of baffles included on the item.ARNE
Baffle Quantity:
1
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Any acceptable
MRC:
The location of the inlet.ARNJ
Inlet Location:
Centrally located in end section of body
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
1.313 inches
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARNW
Inlet Thread Size:
1-1/4-11-1/2
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of specific diameters of an inlet.ARNX
Inlet Thread Series Designator:
Npt
MRC:
Indicates the location of the thread on the inlet.ARSP
Inlet Thread Location:
Internal
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
1 perforated
MRC:
Indicates the location/s/ of the nonconnection outlet on the item.ARXZ
Nonconnection Outlet Location:
Centrally located in end section of body
MRC:
Designates the size of the nonconnection outlet included on the item.ARYA
Nonconnection Outlet Size:
5 in. Dia
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Aluminum alloy
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Aluminum, silicone