رقم الجزء
تجريد
صلاحيه
UOM
NIIN
وحدة القياس:
* special requirements. EA
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.000 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Unthreaded
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
5.620 inches
MRC:
The length of a straight line which passes through the center of the outlet,and terminates at the inside circumference.AJLW
Outlet Inside Diameter:
Any acceptable
MRC:
Indicates the design type of the item.APGF
Design Type:
Dry
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Air
MRC:
The basic design of the muffler.ARND
Muffler Design:
Straight through
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Any acceptable
MRC:
The location of the inlet.ARNJ
Inlet Location:
Centrally located in end section of body
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
2.375 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the outside circumference.ARSQ
Inlet Outside Diameter:
Any acceptable
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the inside circumference.ARTE
Inlet Inside Diameter:
2.735 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the inside circumference.ARTE
Inlet Inside Diameter:
2.765 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the inside circumference.ARTE
Inlet Inside Diameter:
Unable to decode
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Unthreaded
MRC:
The location of the outlet.ARTJ
Outlet Location:
Centrally located in end section of body
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
3.312 inches
MRC:
The length of a straight line which passes through the center of the outlet,with terminated points on the outside circumference.ARWA
Outlet Outside Diameter:
2.719 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, qq-s-766, class 1 or class 2
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel, qq-s-766, class 1 or class 2
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Aluminum