رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Indicating Temperature Control
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+60.0/+100.0 degrees fahrenheit
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
240.0 ac or 240.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.0 or 1.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
Plus 45 to plus 85 degrees f
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
700.0
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
1 pin
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
3.125 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
1.625 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
5.000 inches
MRC:
The intelligence data the item is capable of handling.CKQY
Intelligence Data Handling Capability:
Temperature receiving automatic
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Receiving horizontal scale
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0