Glass Dielect Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Piston
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.312 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.703 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 1.125 inches and 1.249 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.312 inches
MRC:
The minimum and maximum values of the permissible change in capacitance caused by a change in temperature,in parts per million per degree celsius.AEBF
Tempurature Coefficient Of Capacitance Range In Ppm Per Deg Celsius:
-50.0/+50.0 single section
MRC:
The center to center distance between terminals parallel to the diameter of the item.AEBS
Center To Center Distance Between Terminals Parallel To Diameter:
Between 0.172 inches and 0.296 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.030 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the diameter.AEBX
Center To Center Distance Between Mounting Facilities Parallel To Diameter:
Between 0.172 inches and 0.296 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.078 inches and 1.202 inches
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
350.0
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The torque required for the adjustment device.AXGR
Adjustment Device Torque:
Between 1.000 inch-ounces and 10.000 inch-ounces
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
1000000.0 megohms
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 terminal
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 125.0 degrees celsius
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+1.0/+52.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
1000.0 dc continuous single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 slotted screw
MRC:
The drift of capacitance,expressed in picofarads.CTGS
Capacitance Drift In Picofarads:
0.08 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead