رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Signal Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1600.0 hertz
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Black crackle finish
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
Between 50.0 ohms and 150.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 pounds per hour dry and 230.0 pounds per hour with retaining chain
MRC:
Indicates the type of modulation provided.AYYE
Modulation Type:
Pulse
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 10.000 kc accuracy of calibration
MRC:
The fixed number of complete cyclic changes,per unit of time,for which the item is rated.BHFW
Fixed Frequency Rating:
17500.000 hertz and 1850.000 kilohertz
MRC:
The number of fixed frequencies provided.BHFX
Fixed Frequency Quantity:
4
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Provided
MRC:
An indication of the calibrated signal range that is output by the item.BHFZ
Calibrated Signal Output Range:
15 uv to 1 v fixed calibrated output
MRC:
Indicates the location of the modulator on the item.BHGD
Modulator Location:
Internal
MRC:
The number of complete cyclic changes,per unit of time,for which the pulse repetition is rated.BHQF
Pulse Repetition Frequency Rating:
303.03 hertz
MRC:
An indication of the degree of modulation provided.BHQG
Modulation Degree:
58.0 usec pulse
MRC:
The number of alternating current phases.FAAZ
Phase:
Single