رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
tsf160.5-1.6-6xx1
TXT
وصف:
Band Pass Filter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.312 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.875 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
7.375 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+500.0
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.120 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-0.0/+50.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
160.5 megahertz blank
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
50.0 ohms blank
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms blank
MRC:
The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
Input Terminal Manufacturer Code:
98291
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
Input Terminal Identification:
50-048-0000
MRC:
The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
Output Terminal Manufacturer Code:
98291
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
Output Terminal Identification:
50-048-0000
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
1.5 blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slot
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
8.0 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
157.90 megahertz blank and 159.70 megahertz blank and 161.30 megahertz blank and 163.70 megahertz blank
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
159.70 megahertz blank and 161.30 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 blank and 3.0 blank and 3.0 blank and 60.0 blank
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
159.9 megahertz blank and 161.1 megahertz blank
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator: