رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
0.499 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
2.217 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
0.499 inches
MRC:
The length of a straight line which passes through the center of a hole,and terminates at the circumference.AAUB
Hole Diameter:
0.046 inches single end and 0.048 inches single end
MRC:
A measurement between specified points of the hole,in distinction from height.AAZQ
Hole Depth:
0.089 inches single end and 0.090 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.089 inches single end and 0.090 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
Hole Center To Shaft End Distance:
0.090 inches single end and 0.110 inches single end
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
70000.0 feet
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 clamp collar
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Nonventilated
MRC:
The current rating of the control field,expressed in amperes.BFMJ
Control Field Current Rating In Amps:
0.096
MRC:
The impedance rating of the control field,expressed in ohms.BFMK
Control Field Impedance Rating In Ohms:
272.0
MRC:
Indicates the type of winding(s) of the control field.BFML
Control Field Winding Type:
Two windings, series connected or two windings, parallel connected
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Locked rotor
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
4.5 inch-ounces running
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
26.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position and vertical mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.335 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-54.0 operating degrees celsius and 71.0 operating degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
130.0 single no load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.096 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
26.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A1 first style single end and a13 second style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Two input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead