رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Multiple Scale Meter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.380 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.438 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.133 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.750 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.138 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 47.0 hertz and 440.0 hertz
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock resistant and vibration resistant
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Current sensor 1; nut 4; washer 4
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Four hole/stud rectangular/square
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
3.005 inches
MRC:
A measurement taken at right angles to the length of the meter body behind the mounting flange, in distinction from thickness.APSY
Meter Body Width Behind Mounting Flange:
4.126 inches
MRC:
The hue or tint of the background.AQFY
Background Color:
Black single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 screw and 4 unthreaded hole
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+300.0 volts, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+99.9 amperes, ac single indicator 1st range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Terminal
Meter Body Height Behind Mounting Flange:
3.000 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Transformer
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.5 pct of reading porm 1 digit single indicator 2nd range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1 pct of reading porm 1 digit single indicator 1st range
MRC:
The hue or tint of the display.CTQH
Display Color:
Red single indicator all ranges
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
7 screw
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
115.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg