رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Type n connectors; unidirectional power
TXT
وصف:
Fixed Attenuator
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+45.0 degrees celsius
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
1000.0 watts average and 10.0 kilowatts peak
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
20.0
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-0.50/+0.50
MRC:
The specified variation of attenuation caused by a change of temperature,expressed in decibels.ASZM
Temperature Sensitivity Attenuation In Decibels:
0.0004
MRC:
Indicates the type of connection per function.ASZN
Connection Type Per Function:
Female input and male output
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 gigahertz and 1.500 gigahertz